Energy Storage portable Power station
Product Description
ES-2500 energy storage power supply is a high-end fashion power supply product of our company, using aluminum alloy shell, light, portable, fashionable and generous appearance, using power lithium iron phosphate battery total capacity 2304WH(3.2V/720000mAh), advanced manufacturing technology, power output energy, provide AC output, DC output two different voltage mode output, meet the user electronic product charging, and other aspects of electricity demand.This product can be used as UPS power supply and outdoor portable emergency backup power supply.
AC: 220V (110V) AC output
DC output:PD60W*2,QC3.0*2,5V/2.1A*2,One 12V cigarette port .
With a high-brightness LED light (5W).
Display screen displays:percentage of electricity,input display: power and time,output display: power and time,Also with a UPS uninterrupted display.
There are the following two inputs: mains charging (built-in charger) and solar charging.
The output is suitable for a variety of different devices such as drones, portable ventilators, medical devices, mobile phones, tablets, laptops, desktop computers, small printers, various lamps, small fish tanks, photographic equipment, electric scooters etc.Very convenient for users to travel at home, outdoor work, camping picnic, mountaineering and exploration, etc.
Introduction to functions and instructions for use
Panel Description
● When opening the AC or DC switch,first you must turn on the power switch to be valid.(Long press for 3 seconds)
● When using DC output function, press the corresponding DC button to confirm the display DC and DC can be used(Long press for 3 seconds).The display displays the output power and use time in real time.Turn off the button when not used, to avoid power self-consumption(Long press for 3 seconds).The LCD display shows the power surplus, 0~100%.
● When using the AC output function, please press the corresponding AC button to confirm the display AC of the display screen, when the communication can be used, and the display screen displays the output power and use time in real time(Long press for 3 seconds).Turn off the button when not used, to avoid power self-consumption(Long press for 3 seconds).The LCD display shows the power surplus, 0~100%.If the power is insufficient, there will be an alarm prompt. Please charge in time for continuing to use.
● When using the LED light, please turn the corresponding button on.
● When using the UPS function, open the AC, to confirm that the output is normal, and then insert the AC power line into the AC socket. The display will display the UPS characters, indicating normal use.
● When using solar energy to charge the product, within 36V/240W. When the solar panel is connected to charging, the corresponding charging time and power will be displayed on the display screen. If the solar charging icon is not bright, check whether the solar panel is reversed or the solar panel faces the sun (stay at 30 degree angle).
● When the product is charged by the mains , the corresponding charging time and power will be displayed on the display screen during the charging process ( 2.5 hours can charge more than 80%)
● When charging using the car cigarette lighter, it is 12V / 3A. The display charging time and power will be displayed on the display.
● The output power is reduced upon overload when the machine goes into protection.Disconnect load automatically.When the output load is short circuit, the machine enters the protection and disconnects the load to recover automatically.
LCD Display Description
● When the host switch is turned on,the display will light and the battery character C displays the current battery amount of power.The amount of power is shown in five grids. The D shows the current power percentage of the battery.
● After opening the DC switch on the panel, the DC / OUTPUT character in G is lit. When using the DC function, the J displays the current power used, the unit is W(Watt), the K shows the usage time, the unit is Min( minute).
● After opening the AC switch on the panel, the E AC/ PUTPUT character is lit. When using the AC function,the J shows the current power used, and the unit is W(Watt), the K shows the usage time, the unit is Min( minute).
● When using DC and AC functions at the same time, the J shows the total use power, the unit is W(Watt). The K shows the total usage time, unit is Min( minute).
● When charging the host with solar charging function, the display character A is lit. The H Displays the charging power, the I display the battery for a minute, unit is Min( minute).
● When the mains is charging the battery, the character B is lit and the character F is also lit. Indicates that the battery is charged, and the internal MCU detects whether the UPS function is normal, as the normal UPS / POWER character is lit. The H Displays the charging power, the I shows the time when the battery is fully charged, and the unit is Min( minute).
Electrical Parameters
Model |
ES-2500 |
|
Battery capacity |
2304WH(3.2V/720000mAh) | |
Output power |
Rated :2500W Peak: 2600W | |
Input voltage |
110V/50 or 220V /60HZ ( optional)(Built-in charger, about 2.5 hours to charge more than 80%) | |
Output voltage |
220V 50HZ or 110V 60HZ ( optional) | |
DC output |
12V car cigarette lighter port/7A*1 , PD60W*2,QC3.0*2, 5V/2.1A *2 | |
LED light |
5W | |
Solar charging port |
solar charging 30-60V/ 400W | |
Output waveform |
AC pure sine wave inversion |
Lithium iron phosphate battery(LiFePO4 batteries) |
Cycle life is 2000 times | |
Weight |
N.W.: 32.5kg , G.W. : 34.5kg | |
Size |
46.9*24*31cm | |
Color |
Gray body shell, black panel (The main shell color is optional) |
Detailed Parameters
S/N |
Project |
Testing Standard |
1 |
mains input voltage |
220V input or 110V input
(determined according to customer national grid standards) 110V input voltage standard :between 100 and 136V; 220V input voltage standard :between 186 and 246V;
|
2 |
mains input fuse |
220V/8A 110V/10A |
3 |
Inverter AC output voltage |
|
4 |
Inverter AC output frequency |
220V / 50HZ or 110V / 60HZ (Frequency Fixed) |
5 |
Inverter AC ripple voltage |
Less than 700 mV |
6 |
Inverter AC output waveform |
AC pure sine wave |
7 |
Inverter AC rated power |
|
8 |
Discharge efficiency standards
|
C.Test with a rated power of 0.8 times the standard, the efficiency is 76%. |
9 |
Alarm voltage parameters |
|
10 |
Solar charge Standard |
|
11 | Mains charging time |
|
12 |
working temperature and protective temperature |
When the internal heat sink temperature of the host reaches 50-55 degrees, the fan automatically activates the external heat dissipation; when the internal heat sink temperature of the host reaches 85-90 degrees, the machine is automatically turned off, and there is no external output exchange. |
13 |
12V car cigarette lighter output parameters |
|
14 |
USB / 5V output parameters |
|
15 |
PD60W output parameters |
|
16 |
Average boot power consumption |
|
17 |
LED light standard |
|
18 |
Display Content |
|
Schematic diagram of internal PCB board
Function schematic diagram
Packing List
S/N |
Name |
Quantity |
1 |
UPS Power mainframe |
1 |
2 |
AC power line |
1 |
3 |
Instructions |
1 |
4 |
Solar charging line |
(Option) |
5 |
60V 400W solar pane |
(Option) |
Warning and Precautions
When using this product, you should always follow the following notes:
● When the product is not in use, put the product is placed in a ventilated place to avoid rain and wet. It is recommended to charge every 3 months.
● Try to charge the product in a well-ventilated place. When the product is not used, remove the power plug out the product outlet.
● It is forbidden to expose the product to the fire or higher than 80℃, which can lead to a fire explosion and other accidents.
● It is forbidden to use or place the product for a long time in high temperatures (in direct sunlight or in a very hot car), otherwise it may cause internal battery overheating, fire or function failure, and decrease in life.
● It is forbidden to disassemble the product. After the product is disassemble, it may lead to unpredictable risks such as fire, explosion or electric shock.
● It is forbidden to use of damaged wire or plug, or damaged output cable to use the product. There is a risk of electric shock.